Does it support ATS automatic transfer / automatic start?
ATS Automatic Transfer & Auto Start FAQ Q: Does it support ATS automatic transfer / automatic start? A: Yes. Most of our generator sets, emergency power systems, and intelligent control panels support ATS (Automatic Transfer Switch) functionality and automatic start as standard or optional configurations. ⚙️ How It Works Automatic Start: When mains utility power fails, the controller detects the outage and sends a start signal to the engine. The unit reaches rated speed and voltage within seconds (typically 5–15s, depending on model). ATS Automatic Transfer: Once the generator is stable, the ATS switches the load from the utility source to the generator. When mains power restores and stabilizes, the ATS transfers the load back and signals the generator to cool down and shut off automatically. Fully unattended: No manual intervention is required during the entire process — ideal for hospitals, data centers, telecom sites, and remote locations. 🧩 Compatibility & Configuration Standard configuration: Intelligent control modules (Deep Sea, SmartGen, ComAp, etc.) with auto-start logic built-in; ATS panel (motorized or contactor-based) matched to genset capacity (up to 4000A+ available). Optional upgrades: AMF (Automatic Mains Failure) panels integrated into the genset canopy Parallel operation / synchronization with other gensets or the grid Remote monitoring & SCADA integration (Modbus RTU/TCP, SNMP, IoT platforms) Fuel types supported: Diesel, gas, and hybrid systems. 📋 Typical Applications Hospitals & healthcare facilities Data centers & server rooms Telecom base stations Industrial plants & cold storage Commercial buildings & hotels Off-grid renewable + backup hybrid systems ⚠️ Important Notes: ATS capacity must match or exceed the maximum load current. For critical loads, we recommend closed-transition (make-before-break) ATS to avoid power interruption. Proper commissioning and functional testing (simulated mains failure) are essential before handover. 💡 When requesting a quotation, please specify: Rated power (kVA/kW) Single-phase or three-phase Required ATS current rating Priority loads (e.g., life safety, IT equipment) This ensures we configure the correct ATS and controller logic for your application. ✅ In short: Yes, ATS automatic transfer and automatic start are fully supported. Available as standard on most models, and customizable for mission-critical applications. Stable Emergency Power System | NovArk Power For checking suitable generator product for your project — Contact NovArk Power Get a free power system design consultation for your diesel generator set project. Our engineers will analyze your requirements and deliver a tailored generator solution. Request a Consultation View Products This article is for informational purposes only. Specifications and availability may vary by region. Please contact NovArk Power for a confirmed quotation tailored to your project requirements.