Matched power train, one supplier
Engine, alternator, coupling, control panel and circuit breaker are selected as a set and tested as a set. No mismatched sub-assemblies to reconcile on site, and a single warranty covers the whole unit.
Cummins powered ยท 200 - 2400 kW The CCEC Cummins series diesel generator set is built around Chongqing Cummins M, N and K series engines โ the QSM11, QSNT, QSK19, KTA19, QSK38, KTA38 and KTA50 families โ driving brushless, class H alternators. One platform spans 200 kW to 2400 kW, so a mine camp, a hospital or a 2000 kW data centre standby requirement can be sourced from the same Cummins diesel generator range with one documentation set and one spare parts list. Every set is assembled on a heavy-gauge skid, wired to an automatic start control panel and load tested before shipment. Open frame, soundproof canopy and containerised versions are available, at 50 Hz or 60 Hz, with voltage matched to the site. Why this platform Engine, alternator, coupling, control panel and circuit breaker are selected as a set and tested as a set. No mismatched sub-assemblies to reconcile on site, and a single warranty covers the whole unit. Specific fuel consumption across the range sits between 202 and 217 g/kWh at rated load. On a 1200 kW KTA50 set that difference is measurable over a year of prime power operation. Three-side engine access, spin-on filters and a hinged control compartment keep routine service inside a normal maintenance window. Consumables are available through the Cummins global parts network. Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, with ambient conditions of -10 to 40 degrees Celsius and humidity up to 60 percent as the standard reference. Enclosure formats Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next. Product power parameters Seven engine families cover the range. Choose the family first, then the rating; the table below shows the envelope each one covers, while the full model list further down gives dimensions, fuel consumption and dry weight for every build. Power figures refer to the highest rating available within each family; site conditions, altitude and ambient temperature derate apply. Complete range Forty standard builds, from 200 kW prime power to 1760 kW maximum output. Higher ratings within the 2400 kW series ceiling are quoted against project specification. Prime and standby ratings are stated at 0.8 power factor; dimensions and weight refer to the open frame set without fuel tank. Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Voltage and frequency are configured per project. Capacity is verified on a load bank before handover โ see how load bank testing works. Product application scenarios Prime power for crushers, conveyors and dewatering pumps where the grid is weak or absent. The high-displacement QSK38 and KTA38 families hold load steps without excessive frequency dip. Black start, peaking and station blackout backup. KTA50 units at 1200-1500 kW are commonly paralleled for N+1 station service duty. Shipborne auxiliary power, shore-side supply for cold ironing and container terminal backup. Marine configuration options include heat exchangers and classification-ready documentation. Track-side and depot power for maintenance facilities, signalling backup and tunnel construction loads. Drilling rig power, well-site generation and refinery standby, with spark arrestor and remote radiator options for hazardous locations. Standby power for critical loads at 10-second start and full load acceptance, with remote monitoring and automatic transfer switch integration. Testing and handover Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit. Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract. Selection questions Prime power is the rating the set can deliver continuously with a variable load, and standby power is the higher rating available for the duration of a utility outage. In this range standby output is about ten percent above prime, for example 1200 kW prime and 1320 kW standby on the 50 litre KTA50 platform. Yes. Asia, Africa and Europe are usually served at 50 Hz with 230/400 V three-phase, while the Americas, Japan and Korea are typically 60 Hz at 230/440 V. Voltage, frequency and the alternator winding are specified per project, and the nameplate is issued against the confirmed site data. Each unit is assembled, wired and run on a load bank at the factory: insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a load test across the specified rating. Test records travel with the set. Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build. High power ESP projects such as the 2000 kW set recognised in Hunan follow the same engineering route.
CCEC Cummins Series Diesel Generator Set for Prime and Standby Power
Engineered around a genuine Cummins base engine
Matched power train, one supplier
Fuel consumption from 202 g/kWh
Service access that respects downtime
Built to ISO 3046 and ISO 8528
Three enclosure formats, one base engine
Power range by Cummins engine family
Engine family Displacement Cylinders Max power (kW) Typical duty QSM11 14 L 6 270 - 377 Mining drills, plant prime power, mid-size standby QSNT 14 L 6 265 - 392 Construction sites, rental fleets, hospital backup QSK19 19 L 6 447 - 667 Crushers, marine auxiliary, oil field support KTA19 19 L 6 561 - 660 Continuous duty base load, rail depot power QSK38 38 L 12 730 - 1333 Data centres, utility peaking, port operations KTA38 38 L 12 770 - 1210 Industrial base load, mining camps, utilities KTA50 50 L 16 1210 - 1760 Large data centres, power stations, marine CCEC Cummins genset model list and specifications
Unit model Prime (kW) Standby (kW) Max (kW) Engine model Cyl. Disp. (L) Fuel (g/kWh) L x W x H (mm) Weight (kg) QD-263CC 210 231 270 QSM11-G1 6 14 211 2750x980x1600 2300 QD-250CC 200 220 265 QSNT-G6 6 14 214 3000x1050x1750 2600 QD-275CC 220 242 291 QSNT-G7 6 14 217 3000x1050x1750 2700 QD-300CC 240 264 300 QSM11-G2 6 14 217 3000x1050x1750 2700 QD-320CC 255 280.5 321 QSM11-G2 6 14 217 3000x1050x1750 2700 QD-313CC 250 275 325 QSNT-G1 6 14 211 3000x1050x1750 2700 QD-338CC 270 297 330 QSM11-G3 6 14 211 3000x1050x1750 2800 QD-350CC 280 308 358 QSNT-G2 6 14 210 3100x1050x1750 3000 QD-350CC 280 308 350 QSM11-G4 6 14 210 3100x1050x1750 3000 QD-363CC 290 319 360 QSM11-G5 6 14 210 3100x1050x1750 3000 QD-375CC 300 330 377 QSM11-G6 6 14 210 3100x1200x1800 3100 QD-400CC 320 352 392 QSNT-G3 6 14 205 3100x1050x1750 3100 QD-450CC 360 396 448 QSNT-G4X 6 14 209 3100x1050x1750 3200 QD-450CC 360 396 448 QSK19-G15 6 19 207 3300x1400x1970 3400 QD-450CC 360 396 447 QSK19-G14 6 19 207 3300x1400x1970 3400 QD-500CC 400 440 501 QSK19-G13 6 19 205 3600x1400x1970 3900 QD-575CC 460 506 565 QSK19-G12 6 19 217 3600x1500x2000 4200 QD-588CC 470 517 592 QSK19-G6 6 19 204 3600x1500x2000 4200 QD-650CC 520 572 634 QSK19-G4 6 19 215 3600x1500x2000 4800 QD-688CC 550 605 667 QSK19-G11 6 19 216 3600x1500x2000 5000 QD-750CC 600 660 730 QSK38-G8 12 38 217 4300x1700x2350 6500 QD-813CC 650 715 783 QSK38-G7 12 38 216 4500x1800x2350 8000 QD-910CC 728 800.8 878 QSK38-G6 12 38 212 4500x1800x2350 8000 QD-1008CC 806 886.6 970 QSK38-G1 12 38 206 4500x1800x2350 8500 QD-1144CC 915 1006.5 1096 QSK38-G2 12 38 202 4500x1800x2350 9000 QD-1250CC 1000 1100 1224 QSK38-G5 12 38 208 4500x1800x2350 9000 QD-1350CC 1080 1188 1333 QSK38-G19 12 38 209 4500x1800x2350 9000 QD-563CC 450 495 561 KTA19-G8E 6 19 209 3600x1400x1970 3900 QD-625CC 500 550 610 KTA19-G8A 6 19 209 3600x1500x2000 4800 QD-682CC 545 599.5 660 KTA19-G9A 6 19 209 3600x1500x2000 5000 QD-813CC 650 715 770 KTA38-G2E 12 38 209 4500x1800x2350 8000 QD-938CC 750 825 880 KTA38-G5E 12 38 209 4500x1800x2350 8500 QD-1063CC 850 935 990 KTA38-G7E 12 38 209 4500x1800x2350 9000 QD-1125CC 900 990 1100 KTA38-G9E 12 38 209 4500x1800x2350 9000 QD-1250CC 1000 1100 1210 KTA38-G9A 12 38 209 4500x1800x2350 9000 QD-1250CC 1000 1100 1210 KTA50-G3E 16 50 205 5700x2280x2500 11000 QD-1375CC 1100 1210 1320 KTA50-G7E 16 50 205 5700x2280x2500 11500 QD-1500CC 1200 1320 1430 KTA50-G8E 16 50 205 5700x2280x2500 11500 QD-1675CC 1340 1474 1650 KTA50-G15A 16 50 205 5700x2280x2500 12000 QD-1875CC 1500 1650 1760 KTA50-G16A 16 50 205 5700x2280x2500 12500
Where the CCEC Cummins series is specified
Mining and quarrying
Power plants and utilities
Marine and port operations
Rail and transit depots
Oil, gas and petrochemical
Data centres and hospitals
Load tested before it leaves the factory
Choosing the right rating
What is the difference between prime and standby power on a CCEC Cummins set?
Can the generator set be supplied at 60 Hz or at a non-standard voltage?
How is a set from this range tested before shipment?
Need a specific rating, voltage or enclosure?