Googol Power Series High Power Diesel Generator Set 400-3300kW Prime and Standby
Googol Power Series High Power Diesel Generator Set 400-3300kW Prime and Standby
Googol Power Series High Power Diesel Generator Set 400-3300kW Prime and Standby
Googol Power Series High Power Diesel Generator Set 400-3300kW Prime and Standby
Googol Power Series High Power Diesel Generator Set 400-3300kW Prime and Standby
Googol Power Series High Power Diesel Generator Set 400-3300kW Prime and Standby
Model
QD-PG

Item specifics

Rated power
400 - 3300 kW
Standby power
440 - 3630 kW
Rated voltage
400/230 V, adjustable
Rated frequency
50 / 60 Hz
Power factor
0.8
Engine brand
Googol Power (Sino-American JV)
Engine families
PTAA / QTAA / QTA
Cylinders
6 / 8 / 10 / 12 / 16 / 20
Displacement
15 - 108 L
Bore x stroke
135x145 / 135x166 / 185x200 mm
Aspiration
Turbocharged and aftercooled
Alternator
Brushless, class H, AVR
Control panel
Auto start, digital, AMF ready
Configuration
Open frame / silent / container
Fuel consumption
184.9 - 199.3 g/kWh

Review

Description

Googol Power series high power diesel generator set, 400 to 3300 kW, open frame configuration

Googol power · 400 - 3300 kW

Googol Power Series High Power Diesel Generator Set

The Googol Power series diesel generator set runs on engines from Googol Power Technology, the Sino-American joint venture headquartered in Nevada with its manufacturing base in Chongqing. Displacement spans 15 L to 108 L across 6 to 20 cylinders, covering 400 kW to 3300 kW of prime power on one platform — so a mine expansion, a utility peaking plant or a 3000 kW data centre standby can be sourced from the same open frame diesel generator range with one documentation set and one spare parts list.

Each set is assembled on a heavy-gauge skid, wired to an automatic start control panel and load tested before shipment. Open frame, soundproof canopy and containerised builds are available at 50 Hz or 60 Hz, with voltage matched to site.

  • 400 - 3300kW prime power
  • 15 - 108litres displacement
  • 6 - 20cylinders, V configuration
  • 184.9g/kWh from, at rated load

Why this platform

One engine maker from 400 kW to 3300 kW

High-speed, high-power architecture

Googol builds high-speed engines across one of the widest power bands in the Chinese market. A single supplier for a 400 kW site set and a 3000 kW utility unit means shared service procedures, shared tooling and one engineering contact.

Fuel burn from 184.9 g/kWh

Specific consumption across the model list runs from 184.9 to 199.3 g/kWh at rated load. On a large prime rated unit that difference is worth tens of thousands of litres a year, which is why the rating should be matched to the load profile.

Matched power train, one warranty

Engine, alternator, coupling, control panel and breaker are selected together and tested together. One supplier to call, one warranty covering the whole unit, no finger pointing between vendors.

Built to ISO 3046 and ISO 8528

Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, referenced to -10 to 40 degrees Celsius ambient and up to 60 percent relative humidity.

Enclosure formats

Three enclosure formats, one base engine

Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.

Googol Power diesel generator set in open frame, silent canopy and containerised formats

Product power parameters

Power range by Googol engine family

Two engine families cover the range: the 135 mm bore PTAA for compact builds, and the 185 mm bore QTAA for heavy duty. QTA appears in the model list as a second build designation of the same 185 mm engine, so each rating is listed once with its dimensions and weight.

Engine familyBoreCylindersDisplacement (L)Prime power (kW)Positioning
PTAA series135 mm6 - 2015 - 42400 - 1320Compact high-speed build for tight plant rooms
QTAA series185 mm8 - 2043 - 1081000 - 3300Heavy-duty build for base load and utility duty
QTA builds185 mm8 - 2043 - 1081000 - 3300Second build designation of the 185 mm engine

Prime power figures refer to the lowest and highest rating offered within each family; derating applies for altitude and ambient temperature above the reference conditions.

Complete range

Googol Power genset model list and specifications

Twenty-nine listings from 400 kW to 3300 kW prime power, at 0.8 power factor. Where a rating is built on two engine designations they share one row; dimensions and weight refer to the open frame set without fuel tank.

Unit modelPrime (kW)Standby (kW)Max (kW)Engine modelCyl.Disp. (L)Fuel (g/kWh)L x W x H (mm)Weight (kg)
QD-500PG400440490PTAA6L-EG490615198.23400x1300x16503400
QD-563PG450500575PTAA8V-EG575817198.23100x1400x21003050
QD-625PG500550620PTAA8V-EG620817197.63200x1400x21003200
QD-700PG560620690PTAA10V-EG6901021198.13400x1400x21003980
QD-750PG600660740PTAA10V-EG7401021198.13550x1400x21004100
QD-800PG640704815PTAA12V-EG8151225199.33700x1800x22004600
QD-900PG720800900PTAA12V-EG9001225198.83700x1800x22005800
QD-1000PG800880980PTAA16V-EG9801633193.54200x2200x24006480
QD-1125PG90010001120PTAA16V-EG11201633193.64200x2200x24006710
QD-1250PG100011001225PTAA16V-EG12251633193.34200x2200x24007050
QD-1375PG110012001345PTAA20V-EG13452042195.74700x2400x28007880
QD-1500PG120013201480PTAA20V-EG14802042194.24800x2400x28008090
QD-1250PG100011001230QTAA8V-EG1230 / QTA8V-EG1230D843193.34800x2200x26008760
QD-1375PG110012001350QTAA8V-EG1350 / QTA8V-EG1350D843192.44800x2200x26008770
QD-1500PG120013201490QTAA8V-EG1490 / QTA8V-EG1490843192.34800x2200x26009030
QD-1688PG135015001670QTAA10V-EG1670 / QTA10V-EG1670D1054186.95200x2200x285010330
QD-1875PG150016501850QTAA10V-EG1850 / QTA10V-EG18501054186.75200x2200x285010570
QD-2000PG160017601960QTAA12V-EG1960 / QTA12V-EG1960D1265185.95600x2600x290011700
QD-2050PG164018001990QTAA12V-EG1990 / QTA12V-EG1990D1265185.75600x2600x290011850
QD-2250PG180020002210QTAA12V-EG2210 / QTA12V-EG22101265185.05600x2600x290011920
QD-2250PG180020002220QTA16V-EG2220D1686186.96100x2600x290014150
QD-2500PG200022002440QTAA16V-EG2440 / QTA16V-EG2440D1686188.36450x2900x330014890
QD-2750PG220024002660QTAA16V-EG2660 / QTA16V-EG2660D1686186.86600x2900x330016770
QD-3000PG240026402940QTAA16V-EG2940 / QTA16V-EG29401686186.86750x2900x330017270
QD-3000PG240026402950QTA20V-EG2950D20108192.07250x2900x330020500
QD-3125PG250027503100QTAA20V-EG3100 / QTA20V-EG3100D20108191.97400x2900x330020800
QD-3250PG260028603200QTAA20V-EG3200 / QTA20V-EG3200D20108191.87400x2900x330021600
QD-3375PG270030003330QTAA20V-EG3330 / QTA20V-EG3330D20108190.87500x2900x330021600
QD-3750PG300033003600QTAA20V-EG3600 / QTA20V-EG360020108190.77600x2900x330021800

Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Voltage and frequency are configured per project. Capacity is verified on a load bank before handover — see how load bank testing works.

Googol Power diesel generator set power range from 400 kW to 3300 kW

Product application scenarios

Where the Googol Power series is specified

01

Mining and quarrying

Prime power for crushers, mills and dewatering at 1000-3300 kW where the grid cannot follow the load. The 185 mm bore engines carry large motor starting steps without excessive frequency dip.

02

Utility peaking and IPP

Peaking, black start and station blackout duty, with parallel operation and load sharing across multiple QD-3000PG class units.

03

Data centres

Standby for hyperscale and colocation halls. 2500-3300 kW ratings match the block sizes used in N+1 and 2N standby arrangements.

04

Marine and shipyard

Shipborne auxiliary and shore-side supply, including yard power for newbuild and repair berths.

05

Rail and infrastructure

Traction substation backup, tunnel construction power and depot supply for heavy maintenance facilities.

06

Oil, gas and petrochemical

Drilling rig power, well-site generation and refinery standby, with remote radiator and spark arrestor options.

High power diesel generator set applications: mining, utilities, data centres, marine, rail, oil and gas

Testing and handover

Load tested before it leaves the factory

Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.

Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract. See also the questions to ask a generator manufacturer before placing a high power order.

Googol Power generator set under load bank testing before shipment

Selection questions

Choosing the right rating

What separates the PTAA and QTAA engine families?

PTAA uses a 135 mm bore and covers 15 to 42 litres across 6 to 20 cylinders, which suits 400 to 1320 kW where floor space and weight matter. QTAA uses a 185 mm bore, spans 43 to 108 litres and covers 1000 to 3300 kW, with the higher displacement carrying base load duty more comfortably. Ratings overlap between roughly 1000 and 1320 kW, and the choice there comes down to footprint, weight and fuel burn rather than capacity.

Can two or more 3000 kW sets run in parallel?

Yes. Sets are supplied with electronic governing and compatible control panels for load sharing, and paralleling switchgear can be quoted with the order. For N+1 standby the usual arrangement is three or four units sharing the load, with one held as a spare, which also keeps the step load per unit within the block load acceptance of the engine.

What fuel consumption should be allowed for?

Specific fuel consumption across the model list sits between 184.9 and 199.3 g/kWh at rated load. On a 3000 kW prime rated unit that is roughly 560 kg per hour at full load, so bulk tank sizing and day-tank autonomy should be calculated against the site load profile rather than the nameplate rating.

Need a specific rating, voltage or enclosure?

Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build around the same engine platform.

Browse open frame generator sets