Perkins Series Industrial Diesel Generator Set 7-1800kW Prime and Standby
Perkins Series Industrial Diesel Generator Set 7-1800kW Prime and Standby
Perkins Series Industrial Diesel Generator Set 7-1800kW Prime and Standby
Perkins Series Industrial Diesel Generator Set 7-1800kW Prime and Standby
Perkins Series Industrial Diesel Generator Set 7-1800kW Prime and Standby
Perkins Series Industrial Diesel Generator Set 7-1800kW Prime and Standby
Model
QD-P

Item specifics

Rated power
7 - 1800 kW
Standby power
8 - 1980 kW
Rated voltage
400/230 V, adjustable
Rated frequency
50 / 60 Hz
Power factor
0.8
Engine brand
Perkins (UK)
Engine series
400 / 1100 / 1200 / 1500 / 2000 / 4000
Cylinders
3 / 4 / 6 / 8 / 12 / 16
Displacement
1.1 - 61.2 L
Aspiration
Naturally aspirated / turbo / turbo aftercooled
Alternator
Brushless, class H, AVR
Control panel
Auto start, digital, AMF ready
Configuration
Open frame / silent / container
Fuel consumption
200 - 220 g/kWh
Standard
ISO 3046 / ISO 8528

Review

Description

Perkins series diesel generator set, 7 to 1800 kW, open frame configuration

Perkins powered · 7 - 1800 kW

Perkins Series Diesel Generator Set from 7 kW to 1800 kW

The Perkins series diesel generator set covers the whole Perkins line in one catalogue: 400, 1100, 1200/1500, 2000 and 4000 series engines from 1.1 L to 61.2 L, three to sixteen cylinders, and 7 kW to 1800 kW of prime power. One supplier for a 9 kVA telecom set and an 1800 kW data centre standby means one spare parts policy, one service procedure and one engineering contact across a fleet, which is the reason most of our repeat buyers standardise on it — see the full Perkins diesel generator range.

Each set is assembled on a fabricated skid, wired to an automatic start control panel and load tested before shipment. Open frame, soundproof canopy and containerised builds are available at 50 Hz or 60 Hz, with voltage and phase matched to the site.

  • 7 - 1800kW prime power
  • 1.1 - 61.2litres displacement
  • 3 - 16cylinders
  • 200g/kWh fuel from, at rated load

Why this platform

One engine range, from 9 kVA to 2250 kVA

Genuine Perkins base engine

Perkins has supplied diesel engines for more than eighty years and builds the 400 through 4000 series in volume, so parts availability and service documentation are not a project risk. The engine model on the nameplate tells you exactly which build you have.

Fuel burn from 200 g/kWh

Specific consumption across the model list runs from 200 to 220 g/kWh at rated load. On a 300 kW prime rated set that is roughly 60 kg per hour, so day-tank autonomy should be calculated against the load profile rather than the nameplate.

Ratings that follow the market

Model numbers follow the kVA class used in the Chinese market, while the specification columns are kW at 0.8 power factor. Both are stated on the page so an export buyer can quote either without conversion errors.

Built to ISO 3046 and ISO 8528

Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, referenced to -10 to 40 degrees Celsius ambient and up to 60 percent relative humidity.

Enclosure formats

Three enclosure formats, one base engine

Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.

Perkins diesel generator set in open frame, silent canopy and containerised formats

Product power parameters

Power range by Perkins engine series

Five engine series carry the range. Pick the series by duty first, then the rating; the model list further down gives engine model, fuel consumption, dimensions and weight for every build.

Engine seriesDisplacementCylindersPrime power (kW)Typical duty
400 series1.1 - 2.2 L3 - 47 - 16Compact sets for telecom, retail and light standby
1100 series3.3 - 4.4 L3 - 424 - 80Construction, rental fleets and small industry
1100 - 1600 six cylinder6.6 - 9.7 L6108 - 240Commercial buildings, healthcare and water utilities
2000 series13 - 18.1 L6280 - 520Industrial prime power and large facility standby
4000 series22.9 - 61.2 L6 - 16600 - 1800Data centres, utilities, marine and heavy industry

Prime power figures are the lowest and highest rating offered within each series; derating applies for altitude and ambient temperature above the reference conditions.

Complete range

Perkins series genset model list and specifications

Forty-three listings from 7 kW to 1800 kW prime power at 0.8 power factor. Where the same rating appears twice, the two rows are different engine builds of the same set; dimensions and weight refer to the open frame set without fuel tank.

Unit modelPrime (kW)Standby (kW)Max (kW)Engine modelCyl.Disp. (L)Fuel (g/kWh)L x W x H (mm)Weight (kg)
QD-9P789.5403D-11G31.12101320x552x1180330
QD-10P899.5403A-11G131.12001320x552x1180330
QD-13P101113.5403D-15G31.52001320x552x1180380
QD-13P101113.5403A-15G131.52001320x552x1180380
QD-15P121315.1403A-15G231.52001320x552x1180380
QD-20P161820.6404D-22G42.22001320x552x1180460
QD-20P161820.6404A-22G142.22101320x552x1179470
QD-30P242630.41103A-33G33.32141450x970x1360830
QD-45P364046.51103A-33TG133.32181930x1120x1360920
QD-60P485360.51103A-33TG233.32001930x1120x1360970
QD-65P525765.61104A-44TG144.42001930x1120x13601100
QD-80P647080.51104A-44TG244.42151930x1120x13601200
QD-80P647082.51104C-44TAG144.42001930x1120x13601200
QD-100P80881031104C-44TAG244.42142090x1120x13701400
QD-135P1081191371106A-70TG167.02002500x1120x14701600
QD-150P120132153.61106A-70TAG267.02202500x1120x14701600
QD-181P145160179.81106A-70TAG367.02162500x1120x14701600
QD-200P160176196.31106A-70TAG467.02132500x1120x14701600
QD-225P1801982281306A-E87TAG468.72002870x900x16901800
QD-225P1801982361506A-E88TAG268.82002870x900x16901800
QD-250P2002202581506-E88TAG368.82002870x900x16901890
QD-250P2002202501306A-E87TAG668.72102870x900x16901890
QD-275P2202402731606A-E93TAG469.32122900x900x16901900
QD-275P2202402811506A-E88TAG468.82002900x900x16901900
QD-300P2402603121606A-E93TAG569.32003000x900x16902100
QD-300P2402603071506A-E88TAG568.82003000x900x16902100
QD-350P2803083682206C-E13TAG26142103400x1130x20202800
QD-400P3203504132206C-E13TAG36142103400x1130x29252900
QD-450P3603954512506C-E15TAG16152133760x1130x20603450
QD-500P4004404952506C-E15TAG2615.22143700x1110x21403960
QD-600P4805286282506C-E18TAG1A618.12143760x1540x21303970
QD-650P5205706282806A-E18TAG2618.12143760x1540x21304080
QD-750P6006607174006-23TAG2A622.922054290x1912x22866060
QD-800P6407007864006-23TAG3A622.922054290x1912x22866260
QD-900P7207908824008TAG1A830.5612004940x2040x24506920
QD-1000P8008809854008TAG2A830.62054940x1900x22507350
QD-1250P1000110012244012-46TWG2A1245.82105400x1780x26009060
QD-1350P1080118813214012-46TWG3A1245.8422005400x1780x26009160
QD-1500P1200132014594012-46TAG2A1245.82045100x1900x24409720
QD-1710P1368150514964012-46TAG3A1245.82055220x2210x249010890
QD-1850P1480162817414016TAG1A1661.22075930x2300x302015500
QD-2000P1600176019374016TAG2A1661.22075730x2300x302015500
QD-2250P1800198021834016-61TRG31661.22055730x2300x302015500

Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Voltage, frequency and phase are configured per project. Capacity is verified on a load bank before handover — see how load bank testing works and the spare parts list worth stocking for a fleet of this size.

Perkins diesel generator set power range from 7 kW to 1800 kW

Product application scenarios

Where the Perkins series is specified

01

Telecom and retail

7 to 80 kW sets for base stations, shops and small offices, where a compact footprint and a single-phase option matter more than headline output.

02

Healthcare and water

Standby for clinics, laboratories and pumping stations between 100 and 300 kW, with automatic transfer and remote alarm reporting.

03

Construction and rental

Site power for 24 to 200 kW duties, with skid-mounted builds that survive transport and a control panel that rental fleets can standardise on.

04

Commercial buildings

Standby for offices, hotels and shopping centres in the 200 to 650 kW band, sized against lift, HVAC and life-safety loads.

05

Data centres

N+1 standby from 600 to 1800 kW on the 4000 series, with 10-second start, load acceptance and paralleling for hall-level redundancy.

06

Marine and port

Shipborne auxiliary and shore-side supply, including yard power for shipyards and repair berths.

Perkins diesel generator set applications: telecom, healthcare, construction, commercial buildings, data centres, marine

Testing and handover

Load tested before it leaves the factory

Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.

Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract.

Perkins generator set under load bank testing before shipment

Selection questions

Choosing the right rating

Why do the model names not match the kW figures?

The QD number follows the kVA rating used in the Chinese market, while the specification columns are in kW at 0.8 power factor. QD-2250P is therefore 2250 kVA class, rated 1800 kW prime and 1980 kW standby. For export enquiries it is safer to quote the kW figure and the required voltage.

Which Perkins series should a 300 kW project use?

At 300 kW the choice sits between the 1606 and 1506 six-cylinder builds in the 8.8 litre class, or stepping up to the 2206 at 13 litres for heavier load cycles. The larger displacement costs more weight and floor space but holds block loads and continuous duty more comfortably, so the duty cycle rather than the rating should drive the decision.

Can these sets be supplied to EU or US emissions requirements?

Perkins builds the same engine families to several emissions tiers. The build supplied is agreed at order stage against the destination market, and the engine model on the nameplate identifies the tier. Where a project needs a specific approval, state it in the enquiry so the correct build is quoted rather than a standard set.

Need a specific rating, voltage or enclosure?

Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build around the same Perkins engine.

Browse Perkins generator sets