Shanghai powered ยท 8 - 1800 kW
Shanghai Power Series Diesel Generator Set from 8 kW to 1800 kW
The Shanghai Power series covers one of the widest single-source ranges we build: 3, 4, 6 and 12 cylinder Shanghai engines from 1.1 L to 57.2 L, and 8 kW to 1800 kW of prime power from one catalogue. A telecom set and a 2 MW data centre standby can therefore be bought, commissioned and kept running under one spares policy and one service contact โ see the full Shanghai diesel generator range.
The engines come from Shanghai New Power Automotive Technology, the SAIC Group engine works founded in 1947 and listed on the Shanghai Stock Exchange since 1993. Each set is assembled on a fabricated skid, wired to an automatic start control panel and load tested before shipment, in open frame, soundproof canopy or containerised form at 50 Hz or 60 Hz.
- 8 - 1800kW prime power
- 1.1 - 57.2litres displacement
- 3 - 12cylinders, inline and V12
- 188g/kWh fuel from, at rated load
Why this platform
One engine range, from 10 kVA to 2250 kVA
SAIC-owned engine works
Shanghai New Power Automotive Technology has built diesel engines since 1947 and still manufactures the 3Z through 12KTA families in volume. The engine model on the nameplate identifies the build, and parts support runs through a domestic dealer network of more than a thousand service points.
Fuel burn from 188 g/kWh
Specific consumption across the model list runs from 188 to 235 g/kWh at rated load, with the large twelve-cylinder builds at the efficient end. On a 1500 kW prime rated set that is roughly 282 kg per hour, so day-tank autonomy should be calculated against the load profile rather than the nameplate.
Ratings that follow the market
Model numbers follow the kVA class used in the Chinese market, while the specification columns are kW at 0.8 power factor. Both are stated on this page so an export buyer can quote either without conversion errors.
Built to ISO 3046 and ISO 8528
Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, referenced to -10 to 40 degrees Celsius ambient and up to 60 percent relative humidity, with derating stated for altitudes above 1000 m.
Enclosure formats
Three enclosure formats, one base engine
Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.
Product power parameters
Power range by Shanghai engine family
Nine engine families carry the range. Pick the family by duty first, then the rating; the model list further down gives engine model, fuel consumption, dimensions and weight for every build.
Prime power figures are the lowest and highest rating offered within each family; derating applies for altitude and ambient temperature above the reference conditions.
Complete range
Shanghai Power series genset model list and specifications
Fifty-nine listings from 8 kW to 1800 kW prime power at 0.8 power factor. Where a model code repeats, each row is a different engine build of the same rating โ QD-563SC, for example, is offered on both the 6KTAA25 six-cylinder and the 12GTAA27 V12. Dimensions and weight refer to the open frame set without fuel tank.
Standby ratings are limited to the duration of a utility outage and are not continuous ratings. The 1500 kW build is printed as QD-1500PG in the source catalogue and is listed here as QD-1500SC, its series designation. Voltage, frequency and phase are configured per project. Capacity is verified on a load bank before handover โ see how load bank testing works and the spare parts list worth stocking for a fleet of this size.
Product application scenarios
Where the Shanghai Power series is specified
01
Telecom and retail
8 to 80 kW sets for base stations, shops and small offices, where a compact footprint and a single-phase option matter more than headline output.
02
Construction and rental
Site power from 40 to 200 kW, with skid-mounted builds that survive transport and a control panel rental fleets can standardise on.
03
Healthcare and water
Standby for clinics, laboratories and pumping stations between 110 and 400 kW, with automatic transfer and remote alarm reporting.
04
Commercial buildings
Standby in the 200 to 660 kW band, sized against lift, HVAC and life-safety loads rather than total connected load.
05
Manufacturing plants
Prime and standby power for production lines, with the 8.9 to 25.2 litre six-cylinder builds holding motor starting and block loads.
06
Data centres and utilities
N+1 standby from 720 to 2000 kW on the 25 to 57 litre six- and twelve-cylinder engines, with 10-second start and paralleling.
Testing and handover
Load tested before it leaves the factory
Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.
Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract.
Selection questions
Choosing the right rating
Why do the model names not match the kW figures?
The QD number follows the kVA class used in the Chinese market, while the specification columns are kW at 0.8 power factor. QD-2250SC is therefore a 2250 kVA class set, rated 1800 kW prime and 2000 kW standby. For export enquiries it is safer to quote the kW figure and the required voltage.
Why does the same model code appear more than once in the list?
Because the same rating is offered on more than one engine build. QD-563SC, for example, is listed on the 25.2 litre six-cylinder 6KTAA25 and again on the 26.6 litre V12 12GTAA27 at a different weight and fuel figure. The largest set of the family, QD-688SC, appears on four builds. Compare engine model, weight and foot-print, not the unit code alone, before specifying.
Which build should a 400 kW project use?
At 400 kW the choice sits between the 6ETAA12.8 six-cylinder at 12.8 litres and stepping up to the 25.2 litre 6KTAA25. The larger displacement costs weight and floor space but holds continuous duty and block loads more comfortably, so the duty cycle rather than the rating should drive the decision.
Need a specific rating, voltage or enclosure?
Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build around the same Shanghai engine.
Browse Shanghai generator sets