Yuchai powered ยท 40 - 3000 kW
Yuchai Series Diesel Generator Set from 40 kW to 3000 kW
The Yuchai series covers the whole Guangxi Yuchai line in one catalogue: 4, 6, 12, 16 and 20 cylinder engines from 2.5 L to 105.56 L, and 40 kW to 3000 kW of prime power. A 50 kVA telecom set and a 3 MW data centre standby can therefore be bought, commissioned and kept running under one spares policy and one service contact โ see the full Yuchai diesel generator range.
The engines come from Guangxi Yuchai Ship Electric Power, the largest manufacturer of diesel engines in China. The sets are built on a fabricated skid with a large power reserve, stable governing and low emissions, and the engine overhaul interval is rated at more than 10,000 hours. Open frame, soundproof canopy and containerised builds are available at 50 Hz or 60 Hz.
- 40 - 3000kW prime power
- 2.5 - 105.56litres displacement
- 4 - 20cylinders, inline to V20
- 192g/kWh fuel from, at rated load
Why this platform
One engine range, from 50 kVA to 3750 kVA
Yuchai base engine
Guangxi Yuchai Ship Electric Power builds the 4-cylinder YC4D through the 20-cylinder YC20VTD in volume, and the overhaul interval is rated above 10,000 hours. The engine model on the nameplate identifies the build, and the same block is used across the marine and land product lines.
Fuel burn from 192 g/kWh
Specific consumption across the model list runs from 192 to 210 g/kWh at rated load, with the large V12 and V16 builds at the efficient end. On a 2000 kW prime rated set that is roughly 392 kg per hour, so day-tank autonomy should be calculated against the load profile rather than the nameplate.
Ratings that follow the market
Model numbers follow the kVA class used in the Chinese market, while the specification columns are kW at 0.8 power factor. Both are stated on this page so an export buyer can quote either without conversion errors.
Built to ISO 3046 and ISO 8528
Ratings, governing and load acceptance follow ISO 3046 and ISO 8528 practice, referenced to -10 to 40 degrees Celsius ambient and up to 60 percent relative humidity, with derating stated for altitudes above 1000 m.
Enclosure formats
Three enclosure formats, one base engine
Open frame for plant rooms and containerised power stations, soundproof canopy where noise limits apply, and ISO container builds for sea freight. Engine, alternator and control panel stay the same across formats, so spare parts, wiring diagrams and operating procedures carry over from one build to the next.
Product power parameters
Power range by Yuchai engine family
Twelve engine families carry the range. Pick the family by duty first, then the rating; the model list further down gives engine model, fuel consumption, dimensions and weight for every build.
Prime power figures are the lowest and highest rating offered within each family; derating applies for altitude and ambient temperature above the reference conditions.
Complete range
Yuchai series genset model list and specifications
Sixty listings from 40 kW to 3000 kW prime power at 0.8 power factor. Where a model code repeats, each row is a different engine build of the same rating โ QD-1250YC, for example, is offered on the YC6TF, the YC6C and the V12 YC12VTD. Dimensions and weight refer to the open frame set without fuel tank.
Standby ratings are limited to the duration of a utility outage and are not continuous ratings. Where the source catalogue leaves the prime figure blank for an alternative build of the same model, the rating repeats that of the other build and is filled in here. On the four largest V16 builds the catalogue's max power figure is lower than the set's own standby rating, so it is quoted as on request against the engine datasheet rather than repeated. Voltage, frequency and phase are configured per project. Capacity is verified on a load bank before handover โ see how load bank testing works and the spare parts list worth stocking for a fleet of this size.
Product application scenarios
Where the Yuchai series is specified
01
Telecom and retail
40 to 110 kW sets for base stations, shops and small offices, where a compact footprint and a single-phase option matter more than headline output.
02
Construction and rental
Site power from 60 to 400 kW, with skid-mounted builds that survive transport and a control panel rental fleets can standardise on.
03
Healthcare and water
Standby for clinics, laboratories and pumping stations between 120 and 500 kW, with automatic transfer and remote alarm reporting.
04
Commercial buildings
Standby in the 400 to 1000 kW band, sized against lift, HVAC and life-safety loads rather than total connected load.
05
Data centres
N+1 standby from 1200 to 3000 kW on the V12 and V16 builds, with 10-second start, load acceptance and paralleling for hall-level redundancy.
06
Marine and port
Shipborne auxiliary and shore-side supply, including the 16- and 20-cylinder builds used for yard power and repair berths.
Testing and handover
Load tested before it leaves the factory
Every set is assembled on its skid, wired to the control panel and run on a load bank before shipment. Insulation resistance and winding checks, governor and AVR setting, safety shutdown verification and a stepped load test are recorded against the serial number, and the test sheet travels with the unit.
Where a project requires it, third-party witness testing, a documented fuel consumption curve and a site acceptance procedure are agreed in the contract.
Selection questions
Choosing the right rating
Why do the model names not match the kW figures?
The QD number follows the kVA class used in the Chinese market, while the specification columns are kW at 0.8 power factor. QD-2500YC is therefore a 2500 kVA class set, rated 2000 kW prime and 2200 kW standby. For export enquiries it is safer to quote the kW figure and the required voltage.
Why does the same model code appear more than once in the list?
Because the same rating is offered on more than one engine build. QD-1250YC, for example, is listed on the 31.75 litre YC6TF, the 39.58 litre YC6C and the 39.2 litre V12 YC12VTD, at three different weights and foot-prints. Compare engine model, weight and dimensions, not the unit code alone, before specifying.
Which build should a 1000 kW project use?
At 1000 kW the choice sits between the 28 litre YC6TH six-cylinder, the 31.75 litre YC6TF and the V12 YC12VTD. The V12 is the shortest of the three on the floor but heavier and thirstier at part load; the six-cylinder holds continuous duty more comfortably. The duty cycle, not the rating, should drive the decision, and the max power column tells you how much headroom the engine has over the set rating.
Need a specific rating, voltage or enclosure?
Send the site conditions and load profile. We will confirm the rating from this range, or size a custom build around the same Yuchai engine.
Browse Yuchai generator sets